3. SETUP
Fuse Replacement
CAUTION! The RokBox™ EXA utilizes a high-output switch-mode
power supply with an internal fuse. Under normal operating condi-
tions,thefuseshouldnotrequirereplacement.Thefuseiseld
replaceable,howeveritisanadvancedproceduresuitedtoqualied
individuals.ShouldyourRokBox™EXAfuserequirereplacement,
please contact Blizzard Lighting for instructions, or to return your unit
for service.
Connecting A Bunch of RokBox™ EXA Fixtures
You will need a serial data link to run light shows using a DMX-512
controllerortorunshowsontwoormorexturessettosyncinmas-
ter/slaveoperatingmode.Thecombinednumberofchannelsrequired
byallthexturesonaserialdatalinkdeterminesthenumberofx-
tures the data link can support.
Fixtures on a serial data link must be daisy chained in one single line.
Also,connectingmorethan32xturesononeserialdatalinkwithout
the use of a DMX optically-isolated splitter may result in deterioration
of the digital DMX signal.
The maximum recommended cable-run distance is 500 meters (1640
ft).Themaximumrecommendednumberofxturesonaserialdata
linkis32xtures.
Data/DMX Cabling
Tolinkxturestogetheryou’llneeddatacables.Youshouldusedata-
gradecablesthatcancarryahighqualitysignalandarelessproneto
electromagnetic interference.
Forinstance,Belden©9841meetsthespecicationsforEIARS-485
applications. Standard microphone cables will “probably” be OK, but
note that they cannot transmit DMX data as reliably over long distanc-
es. In any event, the cable should have the following characteristics:
2-conductor twisted pair plus a shield
Maximum capacitance between conductors – 30 pF/ft.
Maximum capacitance between conductor & shield – 55 pF/ft.
Maximum resistance of 20 ohms / 1000 ft.
Nominal impedance 100 – 140 ohms